Model: EP1240
Product: Eathing bonding plug
Connector to Earth Resistance 0.9-1.1M Ohms
Specification:
EP1240-1 U.K. Earth Bonding Plug with 1 x 10mm stud
EP1240-2 U.K. Earth Bonding Plug with 1 x 10mm Stud with 1M Resistor
EP1240-3 U.K. Earth Bonding Plug with 3 x 10mm stud
EP1240-4 U.K. Earth Bonding Plug with 3x4mm Banana sockets
EP1240-5 U.K. Earth Bonding Plug with 1 x 10mm stud+2x4mm Banana sockets
EP1240-6 U.K. Earth Bonding Plug with 1 x 10mm stud and 2 x M5 Posts
EP1240-7 U.K. Earth Bonding Plug wih 1 x 10mm stud and 2 x 4mm male stud
Dimensions 65*60*50mm.
Colour/Material Yellow ABS
Weight 80g
EP1240-1 U.K. Earth Bonding Plug with 1 x 10mm stud
EP1240-2 U.K. Earth Bonding Plug with 1 x 10mm Stud with 1M Resistor
EP1240-3 U.K. Earth Bonding Plug with 3 x 10mm stud
EP1240-4 U.K. Earth Bonding Plug with 3x4mm Banana sockets
EP1240-5 U.K. Earth Bonding Plug with 1 x 10mm stud+2x4mm Banana sockets
EP1240-6 U.K. Earth Bonding Plug with 1 x 10mm stud and 2 x M5 Posts
EP1240-7 U.K. Earth Bonding Plug wih 1 x 10mm stud and 2 x 4mm male stud
EP1240-21 Switherland Earthing Plug
EP1240-22 USA Earthing Plug
EP1240-31/32 ESD Earthing Facility
EP1240-41/42 ESD Plastic Earthing Plug
EP1240-51/52 ESD Box Earthing Plug
EP1240-61 ESD Male Plug
Features
The plug fits directly in to the mains supply socket, connecting with only the earth
conductor. Live and Neutral pins have been molded in insulating plastic, fitting into
the supply socket but completely dormant.
At the front of the plug are connectors linked via 1M Ohm resistors to the earth pin
inside the plug. The connectors offer a link to ground for connecting cords from the
EPA.
The1M Ohm resistor to each connector offer protection in the event the workstation
becomes live. That protection would limit the current to less than 0.3mA at 240
volts. Should the fault current continue the resistor will open circuit.
Insert the plug into the supply socket making sure it is fully home, then connect the
various elements of the EPA...such as wrist strap cord, bench or floor matting
connection cords. This ensures that the EPA is at the same earth potential. As
generally the workstation has more than one plug socket it is possible to use more
than one EBP if more connections are required.
Warning the plug must only be used for ESD control purposes.
The EBP is sealed and cannot be opened for repair. To test each connection use
a multi-meter from the connector to the earth pin. The reading should be between
0.9 and 1.1M Ohms. As each connection point has its own 1M Ohm resistor, the
resistance between two connectors should be approximately 2M Ohms. All EBP’s
are tested and then packed in a bag.